Introductions
GSC-F2448 solar charge controller is a highly intelligent charge controller with Maximum Power Point Tracking(MPPT), which can charge 12V/24V/48V batteries with battery voltage level automatic identification. Advanced professional MPPT control algorithm is applied to achieve the optimal and intelligent “MPPT + SOC” charge control. It is especially designed to be low own power consumption by applying advanced low-power, high-performance microcontroller, PWM charging mode and other dedicated hardware circuits. The controller is robust, maintenance-free and user-friendly with the reverse polarity protection, lightning protection, electronic fuse and automatic detection of faulty battery,
Benefits&Features
■ Maximum Power Point Tracking of photovoltaic(PV) module
■ Hybrid controller, MPPT+SOC double intelligent control
■ 12V/24V/48V batteries voltage automatic identification
■ Low-loss MOSFET type transistors in parallel
■ Soft switching technology and synchronous rectification technology are applied
■ Multistage charging technology
■ PWM control
■ Load disconnection depending on SOC
■ Temperature compensation
Electronic protection functions
■ Overcharge protection
■ Deep discharge protection
■ Short circuit protection of load and PV module
■ Overtemperature and overload protection
■ Reverse current protection at night
■ Reverse polarity protection of battery, load and PV module
Displays
■ Multi-coloured LEDs indicate operating states
■ Real-time calendar display
■ LCD indicates real-time data
Operation
■ Operation by the control buttons
■ Manual load switch
Certificates
■ Manufactured according to ISO 9001 and ISO 14001
■ Compliant with European Standards (CE)
■ RoHS compliant
Technical Specfications
|
Product Series
|
GSC-F2448
|
|
Battery Voltage
|
■24V;■48V;
24V /48V Automatic Identification;
|
|
Max. Efficiency
|
> 98%
|
|
Own Power Consumption
|
< 30mA
|
|
Rated Charging Current
|
□10A;□20A;□30A;□40A;□50A;□60A;
|
|
Rated Load Current
|
□10A;□20A;□30A;□40A;□50A;□60A;
|
|
Voltage Drop of Charge Circuit
|
< 0.40V
|
|
Voltage Drop of Load Circuit
|
< 0.35V
|
|
Equalization Charge Voltage
|
29.2V/58.4V
(Used only when battery is deep discharged)
|
|
Buck Charge Voltage
|
28.4V/56.8V
|
|
Float Charge Voltage
|
27.2V/54.4V
|
|
Temperature Compensation
|
-3mv/℃/2V
|
|
Control Mode
|
PWM
|
|
Permitted Operation
Temperature Range
|
-20℃ ~ +55℃
|
|
Dimensions L x B x H
|
164×168×55 mm
|


DownLoad